  Datasheet File OCR Text:
  d1u54-d-1200-12-hx4pc series 54mm 1u front end dc-dc power converter d1u54-d-1200-12-hx4pc.a01 page 1 of 6 www.murata-ps.com/support www.murata-ps.com for full details go to www.murata-ps.com/rohs $ ordering guide part number po wer output main output standby output airflow D1U54-D-1200-12-HC4PC 1200w 12v 3.3v back to front d1u54-d-1200-12-ha4pc 5v d1u54-d-1200-12-hc3pc 3.3v front to back d1u54-d-1200-12-ha3pc 5v input characteristics parameter conditions min typ max units dc input voltage operating range -40 -48/-60 -72 vdc turn-on input voltage ramp up -39.5 -40 -40.5 turn-off input voltage ramp down -35.5 -36 -36.5 maximum current @ vin = -48vdc 1200w 40 adc dc input inrush peak current cold start between 0 to 200ms -40 50 apk -72 100 ef? ciency (-48vdc) 20% fl 90 % 50% fl 92 100% fl 90 reverse polarity protection reversed input cables; no internal/external fuse failure +40 +72 vdc output voltage charateristics output voltage parameter conditions min. typical max. units main 12v voltage set point 12 vdc line & load regulation combined regulation 11.6 12.4 ripple & noise1 20mhz bandwidth 120 mv p-p output current -40vdc to -72vdc dc input 0 100a a load capacitance 30,000 f 3.3vsb voltage set point 3.3 vdc line & load regulation combined regulation 3.14 3.46 ripple voltage & noise 1 20mhz bandwidth 120 mv p-p output current 0 6 a load capacitance 10,000 f 5vsb voltage set point 5.0 vdc line & load regulation 4.76 5.24 ripple voltage & noise 1 20mhz bandwidth 120 mv p-p output current 0 4 a load capacitance 10,000 f 1 ripple and noise are measurements are to be performed with a parallel combination of a 0.1f ceramic capacitor and 10f tantalum capacitance on each of the power module output measurement nodes. a short coaxial cable from measurement point to scope shall be used features ? ? 1200w output power (no derating across the full dc input voltage range) ? ? 1.57"(1u) x 12.65" x 2.15" ? ? 92% ef? ciency ? ? 12vdc main output ? ? 3.3vsb or 5vsb output (20w) ? ? >28w/in 3 power density ? ? n+1 redundancy capable; hot plug/swap (up to 8 modules in parallel) ? ? active current sharing on 12v main output; integral mosfet oring ? ? over-voltage, over-current; over-temperature protection ? ? internal variable speed cooling fans ? ? pmbus? power management bus ? ? rohs compliant product overview the d1u54-d-1200-12-hx4pc series are highly ef? cient 1200 watt, dc input front end modules with a 12v main output and a choice of 3.3v or 5v (20w) standby rails. the power module is able to current share with up to eight (8) other power modules of the same type operating in parallel or n+1 redundancy. the supplies may be hot plugged, and include integral isolation devices. the power modules are fully protected from overload and overvoltage and are able to auto-recover from overtemperature faults. a status led is provided on the front panel and additional control and status reporting is provided by hardware logic signals and via a pmbus? digital interface. a low pro? le sub 1u height enclosure provides an excellent power density of >28w/in 3 that is ideal for delivering reliable, ef? cient power to servers; workstations; storage systems and other 12v distributed power systems, including direct operation from intermediate bus converters. cb test certi cate and test report pm www.murata-ps.com / en / 3d / acdc.htm l www.murata-ps.com / en / 3d / acdc.htm l www.murata- p s.com/en/3d/acdc.htm l www.murata-ps.com / en / 3d / acdc.htm l www.murata- p s.com/en/3d/acdc.htm l www.murata-ps.com / en / 3d / acdc.htm l available now at www.murata-ps.com/en/3d/acdc.html
d1u54-d-1200-12-hx4pc series 54mm 1u front end dc-dc power converter d1u54-d-1200-12-hx4pc.a01 page 2 of 6 www.murata-ps.com/support output characteristics parameter conditions min. typ. max. units remote sense (main output) overall compensation at full load; +ve & -ve connections 120 mv output rise (monotonic) 10% to 95% rise time no positive voltage excursion startup time dc ramp up 3s ps_on activation 200 ms transient response 12v, 50-100% or 100-50% step load; 1a/s slew rate 600 mv 3.3/5vsb 50-100% or 100-50% step load 1a/s slew rate 165/250 current sharing accuracy (between sharing modules; up to 8 in parallel) at 100% load 10 % hot swap transients 5% hold up time 1 fl (full load); 48vdc nominal input prior to hold up 1 ms environmental characteristics parameter conditions min. typ. max. units storage temperature range non-condensing -40 70 c operating temperature range 1200w output power 0 55 operating humidity non-condensing 5 90 % storage humidity 595 altitude (no derating at 40c) 3000 m shock non-operating 30 g sinusoidal vibration operational, 0.5g; 5-500hz mtbf telcordia sr-332 m1c1 @ 40c 452 k hours safety approvals (standards) C pending submission csa/ul c22.2 no.60950-1-07, 2nd ed. iec 60950-1:2005, (2nd edition) with am. 1:2009 en 60950-1:2006 + a11:2009 + a1:2010 ce marking per lvd directive 2006/95/ec input fusing internal 60a/170vdc fast blow fuse on the dc line input (tbc) weight 3.15/1.43 lbs/kg protection characteristics output voltage parameter conditions min. typ. max. units n/a over-temperature air inlet temperature; auto re-start 60 65 70 c 12v (main) over-voltage latching; toggle ps_on or recycle dc input to reset 13 14 v over-current for slow overload events a constant current will be sustained for 1sec followed by a latch off that will auto reset in 5secs. for hard (short circuit) events the output will shut down within 50ms and auto restart within 200ms. this cycle will be repeated ten times at which point the output will permanently latch off. the power module will require to be reset by recycling the incoming dc source or toggling ps_on. 115 135 a 3.3vsb over-voltage latching; toggle ps_on or recycle dc input to reset 3.6 4.0 v over-current shutdown followed by auto-recovery 6.5 8.5 a 5vsb over-voltage latching; toggle ps_on or recycle dc input to reset 5.4 6.0 v over-current shutdown followed by auto-recovery 4.5 5.5 a isolation characteristics parameter conditions min. typ. max. units insulation safety rating/test voltage input to output - basic 1000 vrms isolation output to chassis (ground) 500 vdc 1 assumes deployment within systems utilizing dual redundant a and b dc input feeds status indicators conditions green (power) led status amber (fault) led status no incoming dc supply present; power module completely off. led not illuminated led not illuminated standby rail on; main output off; dc input present & correct blinking led not illuminated standby rail on; main output on solid green main output overcurrent; undervoltage, overvoltage warning led not illuminated solid amber fan_fault; overtemperature; standby rail overcurrent, main output overcurrent or overvoltage led not illuminated solid amber power module warning event led not illuminated blinking
d1u54-d-1200-12-hx4pc series 54mm 1u front end dc-dc power converter d1u54-d-1200-12-hx4pc.a01 page 3 of 6 www.murata-ps.com/support output connector and signal interface emissions and immunity characteristic standard compliance conducted emissions fcc 47 cfr part 15 csipr 22/en55022 class a with 6db margin esd immunity iec/en 61000-4-2; level 4; criteria a radiated field immunity iec/en 61000-4-3 level 3; criteria b electrical fast transients/burst immunity iec/en 61000-4-4 level 3; criteria a surge immunity iec/en 61000-4-5 level 3; criteria a rf conducted immunity iec/en 61000-4-6 level 3; criteria a magnetic field immunity iec/en 61000-4-8 3a/m; criteria b voltage dips & interruptions nebs gr-1089-core issue relevant sections and compliance levels tbd nb: with respect to signals columns 5, the italic 1 refers to the shortest level signal pin/power blade; the italic 2 is th e longest signal pin. the shortest pins are the last to make, ? rst to break in the mating sequence.
d1u54-d-1200-12-hx4pc series 54mm 1u front end dc-dc power converter d1u54-d-1200-12-hx4pc.a01 page 4 of 6 www.murata-ps.com/support pin assignments: d1u54-d-1200-12-hxxpc alternative pin assignments: d1u54-d-1200-12-hxxc te connectivity 1926734-2 (power supply) te connectivity 1926734-4 (power supply) pin function description pin function description 6, 7, 8, 9, 10 v1 (+12vout) +12v main output 6, 7, 8, 9, 10 v1 (+12vout) +12v main output 1, 2, 3, 4, 5 +12v rtn/pgnd +12v main output return 1, 2, 3, 4, 5 +12v rtn/pgnd +12v main output return a1 +vsb standby output a1 +vsb standby output b1 +vsb standby output b1 +vsb standby output c1 +vsb standby output c1 +vsb standby output d1 +vsb standby output d1 +vsb standby output e1 +vsb standby output e1 +vsb standby output a2 +vsb_return standby output return a2 +vsb_return standby output return b2 +vsb_return standby output return b2 +vsb_return standby output return c2 unused no end user connection c2 unused no end user connection d2 unused no end user connection d2 unused no end user connection e2 unused no end user connection e2 unused no end user connection a3 aps i2c address protocol selection (select by appropriate pull down resistor a3 ps_kill po wer supply kill; short pin b3 unused no end user connection b3 unused no end user connection c3 sda i2c serial data line c3 sda i 2 c serial data line d3 v1_sense_r remote sense return (-ve) d3 v1_sense_r remote sense return (-ve) e3 v1_sense remote sense (+ve) e3 v1_sense remote sense (+ve) a4 scl i2c serial clock line a4 scl i 2 c serial clock line b4 ps_on_l remote on/off (enable/disable) b4 ps_on_l remote on/off (enable/disable) c4 smb_alert alert signal to host system c4 smb_alert alert signal to host system d4 unused no end user connection d4 ishare current share bus; short pin e4 dc_ok dc input source present & ok e4 dc_ok dc input source present & ok a5 ps_kill po wer supply kill; short pin a5 a0 i 2 c lsb address line b5 ishare current share bus; short pin b5 unused no end user connection c5 pw_ok po wer ok; short pin c5 pw_ok po wer ok; short pin d5 unused no end user connection d5 a1 i 2 c address line e5 present_l po wer module present; short pin e5 present_l power module present; short pin consult murata sales for availability of alternative hxxc model variants. mating connector (output & signals) supplier press fit, straight press fit, right angle solder straight solder right angle te connectivity (tyco) --- --- --- 2-1926739-5 2-1926733-5 (legacy now obsolete) dc input terminal block dinkle enterprise 2 way t erminal block; 40a rating; +ve & -ve dc input cable connections dt -7c-b14w-02
d1u54-d-1200-12-hx4pc series 54mm 1u front end dc-dc power converter d1u54-d-1200-12-hx4pc.a01 page 5 of 6 www.murata-ps.com/support wiring diagram for output current sharing notes +12v main output return v1_sense (main output remote sense) v1_sense_r +12v main output e3 6-10 1-5 d3 dotted lines show optional remote sense connections. optional remote sense lines can be attached to a load that is a distance away from the power supply to improve regulation at the load. d1u54p 12v load b4 a2,b2 a1,b1,c1,d1,e1 fet, bjt, wire or switch (debounced ) to turn on +12v main output vsb load vsb ps_on vsb_return a5 (or a3) ps_kill d1u54p b5 (or d4) ishare ps_kill a5 (or a3) a2,b2 vsb_return ps_on b4 a1,b1,c1,d1,e1 vsb b5 (or d4) d3 v1_sense_r ishare +12v main output return +12v main output v1_sense (main output remote sense) e3 6-10 1-5 1. main 12vdc output: analogue active share bus. the ishare bus (pin b5 or d4) must be connected on all sharing modules. it is not required that the sense signals are con- nected to the remote load for current share to operate correctly. 2. up to eight (8) power modules can be connected in parallel (non-redundant) or n+1 con? guration. the current share bus is an alogue bi-directional (can source or sink current from the ishare bus). the voltage of the bus would measure 8vdc for a single power module at 100% load; for two (2) modules sharing a common load the ishare bus voltage would be 4v for a perfect 50/50 current share scenario. 3. the vsb (standby output) output of the power module can also be connected in parallel; internal output isolation devices are provided however the combined available power is limited to that available from a single power module (3.3v or 5v; 20w) irrespective of the number of modules connected in paral lel.
d1u54-d-1200-12-hx4pc series 54mm 1u front end dc-dc power converter d1u54-d-1200-12-hx4pc.a01 page 6 of 6 www.murata-ps.com/support murata power solutions, inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. the descriptions contained her ein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. speci? cations are subject to cha nge without notice. ? 2015 murata power solutions, inc. murata power solutions, inc. 11 cabot boulevard, mans? eld, ma 02048-1151 u.s.a. iso 9001 and 14001 registered this product is subject to the following operating requirements and the life and safety critical application sales policy: refer to: http://www.murata-ps.com/requirements/ mechanical dimensions optional accessories description part number d1u54-12 output interface connector card d1u54p-12-conc application notes document number description link acan-44 d1u54p-12-conc output interface connector card www.murata-ps.com/data/apnotes/acan-44.pdf acan-58 d1u54-d-12 communications protocol notes 1. dimensions: 1.57" x 12.66" x 2.15" (40.0 x 321.5mm x 54.5mm) 2. safety earth/ground connection via separate dedicated m4 pan head screw connection (located above terminal block)


▲Up To Search▲   

 
Price & Availability of D1U54-D-1200-12-HC4PC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X